Description
NOS ATEX Test & flushing HPU’s are efficient and easy to use units for test & flushing operations, combining two operations frequently done together.
Datablad
| Test & flushing unit in frame | ||
| Approvals | DNV 2.7-1 EN 12079 | |
| Area Classification | ATEX Sone 1 gas group IIA,T5 | |
| Frame Envelope Size | 1500x1500x2000mm (LxWxH) | |
| Weight dry. | 2000kg | |
| Z-015 Type | U99 | |
| Electric motor | 45kw 60BHP | |
| Pump | Mission 2500 5x4x14 | |
| Process Data: | ||
| LP pump | HP Pump | |
| Pump | Marshalsea | Marshalsea |
| Capacity | 0-13,5 lpm | 0-1,4 lpm |
| MWP | 410 bar | 1035 bar |
| Accumulator vol. | 20 L | 10 L |
| NPSH @ Max Capacity | 29 feet | 8 feet |
| 2xOutlet ea pump | ½” BSP | ¼” BSP |
| Inlet tank | ½” BSP | |
| Air supply | 1” Chicago claw | |
| Supply connection | ||
| Power | 400/440v, 50/60hz | |
| Ambient Operating temperature | 0 – 40 °C
(below 0°C contact NOS) |
|