HP1278 HPU

Harben 8.20 & 8.22 ATEX Zone 1 Flushung HPU  DNV 2.7-1

Category: Tag:

Description

NOS Harben HPS’s are a flushing and injection HPU with a radial diaphragm pump that reduces pulsation and gives an even flow, optimal for flushing and injection.

Datablad

Press to Preview PDF: NOS-1278

HPU in Frame
Approvals Norsok Z-015, DNV 2.7-1
Area Classification ATEX Sone 1
Frame Size 1600x1000x1690mm (LxWxH)
M.G.W 2 500kg
Tare 1 130 kg
Max Payload 1 370kg
Z-015 Type U99
Electric motor 34kw
Pump HPU Harben 8.20 or 8.22
Flow & pressure
Pump Type 8.20 8.22
Flow @ 50hz 0-46 lpm 0-60 lpm
Flow @ 60hz 0-54lpm 0-72 lpm
MWP 345 bar 280 bar
Process data
Flow read Flowmeter
Flow control PCV
PRV Yes
Tank 300L
Filter House  
Filter 3my – 0330-TG05
Supply connection
Outlet ½” BSP
Return ½” BSP
Inlet to tank 2” FIG 206 (floater valve)
Inlet / Outlet Cooling water 1” Claw
Air 1” Claw
Power 440v,63A
Ambient Operating temperature 0 – 60 °C

(below 0°C contact NOS)

 

Send us a request regarding HP1278 HPU