Description
NOS Test & flushing HPU’s are a range off HPU’s built with two pumps. One for high pressure & one for high flow to do testing and flushing with one unit. The HPU’s are fully automated and controlled by touch screen.
Datablad
Press to Preview PDF:NOS-HP6369
| HPU in Frame | ||
| Approvals | Norsok Z-015, DNV 2.7-1 | |
| Area Classification | ATEX Sone 1, IIB T3 | |
| Frame Size | 1500x1500x2050mm (LxWxH) | |
| Weight | 1 600kg | |
| Z-015 Type | U99 | |
| Flow & pressure | ||
| LP | HP | |
| Pump Type | MarshalSea
XW1197-43 |
MarshalSea
XW1196-50 |
| Electric motor | 5,5Kw | 15Kw |
| Flow | 0-1,9 lpm | 0-16,5 lpm |
| MWP | 690 bar | 345 bar |
| Accumulator | 25L | 10L |
| Process data | ||
| HMI | 9” touch Screen | |
| Flow control | Frequency control | |
| PRV | Yes | |
| Tank | 200L | |
| Filter LP | DHD110H03B | |
| Filter HP | DHD60H03B | |
| Filter Return | DHD660G03 | |
| Pump Lubrication | Castrol Alfasyn HW150 | |
| Supply connection | ||
| Outlet HP | 3/8” MP | |
| Outlet LP | ½” Tube / fitting on request | |
| Return / Fill | 1 ” Tube / fitting on request | |
| Purge Air | 1” Claw | |
| Power | 400/440v,63A 50/60Hz | |
| Ambient Operating temperature | 0 – 60 °C
(below 0°C contact NOS) |
|